If the guard unreachable_since variable was set, the status "up" was
reported which is wrong. This adds the "down" status followed by the
unreachable_since time value.
Fixes#14184
Signed-off-by: David Goulet <dgoulet@ev0ke.net>
David Goulet finds that when he runs a busy relay for a while with the
latest version of the git code, the number of onionskins handled
slowly dwindles to zero, with total_pending_tasks wedged at its
maximum value.
I conjecture this is because the total_pending_tasks variable isn't
decremented when we successfully cancel a job. Fixed that.
Fixes bug 14741; bugfix not on any released version of tor.
Ordinarily, get_options() can never return NULL, but with
test_status.c mocking, it can. So test for that case.
The best fix here would be to pass the options value to a
bridge_server_mode() function.
After connectivity problems, only try connecting to bridges which
are currently configured; don't mark bridges which we previously
used but are no longer configured. Fixes 14216. Reported by
and fix provided by arma.
It's now possible to use SocksPort or any other kind of port that can use a
Unix socket like so:
SocksPort unix:/foo/bar/unix.sock
Fixes#14451
Signed-off-by: David Goulet <dgoulet@ev0ke.net>
Introduces two new circuit status name-value parameters: SOCKS_USERNAME
and SOCKS_PASSWORD. Values are enclosing in quotes and unusual characters
are escaped.
Example:
650 CIRC 5 EXTENDED [...] SOCKS_USERNAME="my_username" SOCKS_PASSWORD="my_password"
Here is why:
1) v0 descriptors are deprecated since 0.2.2.1 and not suppose to be alive
in the network anymore. This function should only serve v2 version for now
as the default.
2) It should return different error code depending on what's the actual
error is. Right now, there is no distinction between a cache entry not found
and an invalid query.
3) This function should NOT test if the intro points are usable or not. This
adds some load on a function that should be "O(1)" and do one job.
Furthermore, multiple callsites actually already test that doing twice the
job...
4) While adding control event, it would be useful to be able to lookup a
cache entry without having it checking the intro points. There are also
places in the code that do want to lookup the cache entry without doing
that.
Fixes#14391
Signed-off-by: David Goulet <dgoulet@ev0ke.net>